The Boltac Jar Stirrer

Introduction

The Boltac Coagulation & Flocculation Simulator is a device used to simulate the process by which water is cleaned. The addition of both primary and secondary coagulants and coagulant aids can be simulated in this machine (otherwise known as a Jar Stirrer or Jar Tester, or alternatively as a Floc Tester). Knowing how to relate the results of a jar test back to the plant operation is the key to success.

The process being simulated is normally taking place in a vast settling tank, in which up to five million litres can be in process at one time. Once proficient, an operator can gain accurate results using 4 or 6 litres per test. Depending on the design of the process being simulated, the jar test can show results in as little as 30 minutes, compared to up to a number of hours when monitoring the actual process.

If a change is to be made without first ascertaining the amount or direction of the change, costly, (sometimes dangerous), and embarrassing errors can be made. The practised and frequent use of the machine can lead to chemical savings, adherence to performance criteria, and a definite aid to Quality Assurance auditing.

This machine is designed to give many years service, and will do so, given the proper care. We enjoy receiving feedback re our equipment, good we take with pride, and we like to call constructive criticism, please feel free to offer yours

Using the Jar Stirrer

** New Model **
** The Jar Master **
** NOW AVAILABLE **

Specification

Category 1 to 8 Station stirrer either stand-alone or PC controlled.

Four and Six
Station Stirrer
Boltac Jar Stirrer

Specification

Category 4 and 6 Station stirrer
Design Registered Design in N.Z, Australia, U.K., USA., and Canada.
Chassis Easy to clean Stainless Steel, supplied with dust cover.
Paddles/Shafts Removable Stainless Steel. All paddles rotate at precisely the same speed.
Paddle racks Supplied with machine, enables paddles to be supported above the jar, even while machine is running.
Power Supply ******* NEW FEATURE *******

AUTO VOLTAGE SELECTION HAS BEEN ADDED:
The JarStar will run on either of the following power supplies.
110 to 120VAC @ 40hz to 80hz
220 to 240VAC @ 40hz to 80 hz

2 metre standard IEC power plug lead for Australia or New Zealand.

Control Intuitive Mouse controlled interface with large back-lit diaplay, 2 lines of 40 characters, angled for easy viewing.
Manual speed control mode for basic operation. Up to 30 user defined automatic control programs of up to 99 steps in length. 0 to 10 hours in 1 second steps. 0 to 340 RPM in 0.1 RPM steps (+/- 0.3% accuracy).
Speed selectable as either RPM or G value. Selectable water temperature value for automatic G value compensation.
Illumination Diffused, low heat transfer Fluorescent lighting.
Contrast Aperture for insertion of coloured contrast cards.
Jars 1.3 litre. Grade 1 acrylic, square, graduated to 1 litre. (Supplied with machine).
Warranty 12 month warranty on parts and labour.
Documentation Manual supplied. Manual contains wiring diagram, troubleshooting guide, coagulation test procedures, interlaboratory/plant evaluation calculations, suggestions, etc.
Quality Quality control documentation supplied for each machine.
Cover/Strap 4 gang units have dust cover and carry strap as standard, 6 gang units have cover as standard, strap optional
Accessories
  • Simuldose Rack, adds chemical to all jars simultaneously.
  • Machine Link, Multiple stirrers can be linked together as master / slave for synchronised operation..

Design Registration

This Machine is covered by Registered Design Applications in the following countries:

Machine Profile New Zealand New Zealand Registered Design No 24012
Australia Australia Registered Design No 116000
United States US Design Patent No 348,620
Canada Canadian Industrial Design Registration No 76567